TECHNICAL SPECIFICATION
Output
1-Output power capacity
600Watts / 1.0 kVA
2-Max Configurable Power (Watts)
600Watts / 1.0 kVA
3-Nominal Output Voltage
230V
4-Efficiency at Full Load
84.0 %
5-Output Frequency (sync to mains)
50/60 Hz +/-1 Hz
6-Topology
Line Interactive
7-Waveform type
Stepped approximation to a sinewave
8-Output Connections
(4) India 3-pin 6A (Battery Backup)
(2) India 3-pin 6A (selector_surgetitle)
9-Transfer Time
8ms typical : 12ms maximum
Input
1-Nominal Input Voltage
230V
2-Input frequency
50/60 Hz +/- 3 Hz (auto sensing)
3-Input Connections
India 3-pin 6A
4-Cord Length
1.52meters
5-Input voltage range for main operations
150 - 280 V
6-Number of Power Cords
1
7-Efficiency at Full Load
84.0 %
Batteries & Runtime
1-Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
2-Typical recharge time
7.4hour(s)
3-Expected Battery Life (years)
2 - 4
4-RBC Quantity
1
5-Extendable Run Time
1
Communications & Management
1-Interface Port(s)
USB
2-Control panel
Multi-function LCD status and control console
3-Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
1-Surge energy rating
680Joules
2-Data Line Protection
Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100/1000 Base-T Ethernet (RJ-45 connector)
Physical
1-Maximum Height
301mm , 30.1cm
2-Maximum Width
114mm , 11.4cm
3-Maximum Depth
382mm , 38.2cm
4-Net Weight
11.35kg
5-Shipping weight
12.77kg
6-Shipping Height
381mm , 38.1cm
7-Shipping Width
229mm , 22.9cm
8-Shipping Depth
483mm , 48.3cm
9-Color
Black
10-Master Carton Units
2.0
11-Master Carton Weight
27.2
Environmental
1-Operating Environment
0 - 40 °C
2-Operating Relative Humidity
0 - 95 %
3-Operating Elevation
0-3000meters
4-Storage Temperature
-15 - 45 °C
5-Storage Relative Humidity
0 - 95 %
6-Storage Elevation
0-15000meters
7-Audible noise at 1 meter from surface of unit
45.0dBA
Conformance
1-Standard warranty
2 years repair or replace
FEATURES
1-Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
2-Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
3-Audible alarms
Provides notification of changing utility power and UPS power conditions
4-Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
5-Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
6-Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
7-Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
8-Boost and Trim Automatic Voltage Regulation (AVR)
Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
9-Building Wiring Fault Indicator
This LED informs users of potentially dangerous wiring problems in the wall circuit.
10-Cold-start capable
Provides temporary battery power when the utility power is out.
11-Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
12-Disconnected battery notification
Warns when a battery is not available to provide backup power.
13-Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
14-Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
15-Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
16-LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
17-Power-saving outlets
Automatically cuts power to idle equipment to conserve electricity.
18-Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
19-Serial connectivity
Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
20-USB connectivity
Provides management of the UPS via a USB port (not available on all models).
21-User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
22-Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
23-Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
24-Energy Management Function
Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
25-Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
26-Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
27-Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
28-Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
29-Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
30-Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
31-Cold-start capable
Provides temporary battery power when the utility power is out.
Protection
1-Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
2-Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
3-Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Serviceability
1-Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
2-Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.
Manageability
1-Audible alarms
Provides notification of changing utility power and UPS power conditions
2-LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
3-USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
4-Disconnected battery notification
Warns when a battery is not available to provide backup power.
Safety
1-Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Marketing Features
1-Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
2-Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
3-Energy Management Function
Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
4-Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
5-LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.