All Categories

  • All Categories
  • Computers
  • Desktops
  • All in One PC
  • Laptop / Notebook
  • Workstation
  • Convertible Laptops
  • Warranty Extension
  • Server
  • Tower Server
  • Rack Server
  • Backpack
  • Printing & Imaging
  • Laserjet Printers
  • Deskjet Printers
  • All in One Printer
  • Dot Matrix Printers
  • Ink Tank Printers
  • Scanners
  • PC Accessories
  • Keyboard & Mouse
  • Monitors-LED/LCD
  • Power Adapters
  • Laptop Batteries
  • Laptop Screens
  • RAM-Laptop
  • RAM-Desktop
  • Hard Disk Internal
  • Hard Disk External
  • DVD Read Writer
  • Motherboards
  • Processors
  • Cables / Cords
  • Graphic Cards
  • Networking Solution
  • Networking Rack
  • Networking Switches
  • Firewall
  • Wifi Routers
  • Network Accessories
  • UPS - Power Backups
  • Survelliance Security
  • Biometric Systems
  • CCTV Camera
  • DVR System
  • CCTV Accessories
  • DVR Power Supply
  • Application Software's
  • Antivirus Pro
  • Internet Security
  • Total Security
  • Microsoft
  • Data Recovery Software
  • Mobile Security
  • Accounting Software
  • Backup Software's
  • Other Softwares
  • Mobile Accessories
  • Earphones / Earpiece
  • Headphones / Headset
  • Data / USB Cables
  • Mobile Adapters
  • Bluetooth Adapters
  • Other Products
  • Power Banks
  • Speakers
  • Car Chargers
  • Data Card / Wifi Adaptor

APC, 1KVA, Battery, Backup, UPS

APC 1KVA Battery Backup UPS

rating
  • Rs10,620.00
  • Product Code:AI-10-002
  • Availability:100

Product DetailsUPC: 731304286240Brand: APCProduct: NewGeneric Name: UPSModel no.: BR1000G-INWarranty: 1 Year From APCVolumetric Weight: 15 kgTECHNICAL SPECIFICATIONOutput1-Output power capacity600Watts / 1.0 kVA2-Max Configurable Power (Watts)600Watt..

Product Details

UPC: 731304286240

Brand: APC

Product: New

Generic Name: UPS

Model no.: BR1000G-IN

Warranty: 1 Year From APC

Volumetric Weight: 15 kg


TECHNICAL SPECIFICATION


Output

1-Output power capacity

600Watts / 1.0 kVA

2-Max Configurable Power (Watts)

600Watts / 1.0 kVA

3-Nominal Output Voltage

230V

4-Efficiency at Full Load

84.0 %

5-Output Frequency (sync to mains)

50/60 Hz +/-1 Hz

6-Topology

Line Interactive

7-Waveform type

Stepped approximation to a sinewave

8-Output Connections

(4) India 3-pin 6A (Battery Backup)

(2) India 3-pin 6A (selector_surgetitle)

9-Transfer Time

8ms typical : 12ms maximum


Input

1-Nominal Input Voltage

230V

2-Input frequency

50/60 Hz +/- 3 Hz (auto sensing)

3-Input Connections

India 3-pin 6A

4-Cord Length

1.52meters

5-Input voltage range for main operations

150 - 280 V

6-Number of Power Cords

1

7-Efficiency at Full Load

84.0 %


Batteries & Runtime

1-Battery type

Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof

2-Typical recharge time

7.4hour(s)

3-Expected Battery Life (years)

2 - 4

4-RBC Quantity

1

5-Extendable Run Time

1


Communications & Management

1-Interface Port(s)

USB

2-Control panel

Multi-function LCD status and control console

3-Audible Alarm

Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm


Surge Protection and Filtering

1-Surge energy rating

680Joules

2-Data Line Protection

Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100/1000 Base-T Ethernet (RJ-45 connector)


Physical

1-Maximum Height

301mm , 30.1cm

2-Maximum Width

114mm , 11.4cm

3-Maximum Depth

382mm , 38.2cm

4-Net Weight

11.35kg

5-Shipping weight

12.77kg

6-Shipping Height

381mm , 38.1cm

7-Shipping Width

229mm , 22.9cm

8-Shipping Depth

483mm , 48.3cm

9-Color

Black

10-Master Carton Units

2.0

11-Master Carton Weight

27.2


Environmental

1-Operating Environment

0 - 40 °C

2-Operating Relative Humidity

0 - 95 %

3-Operating Elevation

0-3000meters

4-Storage Temperature

-15 - 45 °C

5-Storage Relative Humidity

0 - 95 %

6-Storage Elevation

0-15000meters

7-Audible noise at 1 meter from surface of unit

45.0dBA


Conformance

1-Standard warranty

2 years repair or replace


FEATURES

1-Adjustable voltage sensitivity

Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

2-Adjustable voltage-transfer points

Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

3-Audible alarms

Provides notification of changing utility power and UPS power conditions

4-Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

5-Battery failure notification

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

6-Battery replacement without tools

Enables fast battery replacement, lowering Mean Time to Repair (MTTR).

7-Battery-protected and surge-only outlets

Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

8-Boost and Trim Automatic Voltage Regulation (AVR)

Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.

9-Building Wiring Fault Indicator

This LED informs users of potentially dangerous wiring problems in the wall circuit.

10-Cold-start capable

Provides temporary battery power when the utility power is out.

11-Dataline surge protection

Provides protection of connected equipment from power surges on the data lines.

12-Disconnected battery notification

Warns when a battery is not available to provide backup power.

13-Green mode

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

14-Hot-swappable batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

15-Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

16-LCD graphics display

Text and mimic diagrams that display modes of operation, system parameters and alarms.

17-Power-saving outlets

Automatically cuts power to idle equipment to conserve electricity.

18-Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse.

19-Serial connectivity

Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.

20-USB connectivity

Provides management of the UPS via a USB port (not available on all models).

21-User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

22-Transformer-block spaced outlets

Protect equipment with input transformer blocks without blocking access to other receptacles.

23-Boost and Trim Automatic Voltage Regulation (AVR)

Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

24-Energy Management Function

Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.

25-Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

26-Customizable voltage sensitivity

Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.

27-Customizable voltage-transfer points

Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.

28-Green mode

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

29-Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

30-Battery failure notification

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

31-Cold-start capable

Provides temporary battery power when the utility power is out.


Protection

1-Dataline surge protection

Provides protection of connected equipment from power surges on the data lines.

2-Surge only outlets

Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

3-Battery and surge protected outlets

Back up and protect your hardware and data during power outages, surges and spikes.


Serviceability

1-Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse.

2-Simple battery replacement

Increases UPS availability by allowing quick, easy battery replacement.


Manageability

1-Audible alarms

Provides notification of changing utility power and UPS power conditions

2-LCD Status Display

Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

3-USB connection

Use your PC to access additional power protection and management features for your UPS via a USB Port.

4-Disconnected battery notification

Warns when a battery is not available to provide backup power.


Safety

1-Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.


Marketing Features

1-Boost Automatic Voltage Regulation (AVR)

Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.

2-Battery-protected and surge-only outlets

Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

3-Energy Management Function

Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.

4-Green mode

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

5-LCD Status Display

Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha